Home About Us Lever Meter Process Automation Water Analysis & Water Treatment Instrument Fluid Controlling Contact Us

TEL︰+86-755-83841930
   +86-755-83841939
FAX︰+86-755-83841895
Email︰
marke@sz-victory.com.cn

Process Automation  
 
ADAS Acquisitions Systems ICV307
   

ICV 307

SPECIFICATIONS (t = 25°C)

TYPE

6 COUNTER CHANNELS 32 BITS

INPUTS  
- Per channel Channel "A", channel "B", strobe, clear
- Type Optocoupled, regulated low input current
- Inputs level + 5V, + 12V, + 15V, +24V
- Galvanic isolation Up to 2500V (1mn) to VME
- Filtering Anti-bounce on counter inputs (A + B) software switchable adjustable frequencies of 125KHz, 1MHz, 10MHz
- Max. input frequencies 5 MHz in direct mode (10 meters max cf RS422 distance)

(links to emit devices)

5 MHz in quadruple discriminator mode (X4)

ACCURACY  
- Frequency measurement 10 -4 at 1KHz

- Period measurement

10 -4 at 1KHz

MEANS  
- Internal clock Programmable from 100Hz to 10MHz in decades
- Time bases 2 (programmable from 0.01s to 10s in decades)

- Isolated voltage

5V/400mA by DC/DC with fuse protection for compatibility STB306ISO

OPERATING MODES  

Quadruple, double, single impulse per cycle for increment coders.
Counting up or down of events, measurement of impulse width and frequencies with prepositionable count-up or count-down.
Direct recognition of count-up or count-down modes and possibilities: Hysterisis, inhibition, counting, preloading.
External possibilities and loading and reset software.
Possibility of interrupt after external loading, external clear, overflow, direction loading or end of time base.

VME INTERFACE  
- Access 8 bits or 32 bits for the counter read
- Decoding Uses 128 bytes in the short I/O or standard spaces

- Nb of interrupts

7 on emission (8 different vectors)

POWER SUPPLIES  
- On VME + 5V / ± 0.25V / 2.5A max.

- DC/DC converter

+ 5V / 0.4A isolated (available and compatibility with STB306ISO)

PRESENTATION  
- Format VME double EUROPE / 4Te
- Dimensions in mm 233.35 x 160

- Front panel connectors

3 "D" 25 pins connectors

ENVIRONMENT

 

- Operating temperature

- 20°C to + 70°C

- Storage temperature

- 25°C to + 85°C

- Relative humidity

90 % (without condensation)

EUROPEAN NORMS  
  EMC - EN 61326 - EN 55011 Class A
CE Compliance
ROHS - 2002/95/EC
HOW TO ORDER?

ICV 307

ACCESSORIES

- Terminal blocks

- Cables

STB306, STB504,

WR233, WR251

 

Adas board

 

 

ADAS Acquisitions Systems
  Technology Introduction
  Technology Introduction
  Product Catalog
PCI102
PCI DX6
PCI264
PCI 307
PCI 150
PCI 160
PCI 220
PCI 224
PCI 228
PCI 238
PCI 744
PCI 786
PCI LMC
CPCI SYN
CPCI 1264
CPCI 307
CPCI 1150
CPCI 1224
CPCI 1228
CPCI 412
CPCI 744
CPCI 1786
CPCI LMC
RCV20
ICV196
ICV307
ICV726
ICV150
STB512-514-534
STB532
STB6x2
ICV LMC
ACM
STB504
  Typical Applications
  Specification
OMRON
SIEMNES
EMERSON
SOR Pressure Switch
 