Home About Us Lever Meter Process Automation Water Analysis & Water Treatment Instrument Fluid Controlling Contact Us

TEL︰+86-755-83841930
   +86-755-83841939
FAX︰+86-755-83841895
Email︰
marke@sz-victory.com.cn

Process Automation  
 
ADAS Acquisitions Systems PCI 160
   

Pci StbBciSoftwareAdas Electronique

Description

 

  • Board for general use
  • 16 protected isochronous analog inputs at ± 40V VIN = +/- 10VFS (G = 1)
  • 32 inputs/outputs TTL (2 groups of 16 bits)
  • 8 analog outputs ±10V FS DACs 14 bits
  • ADCs 16 bits 200Ks/s/channel
  • Selectable gains by software on each analog inputs G = 1 ; 2 ; 5 ; 10
  • 15 decimation reports with anti-aliasing protection
  • Numerical filter selectable by channel
  • High accuracy and weak drift (2 x 10-5)
  • IRIG B input or TRIGGER for datation (Master / Slave)
  • PLL (Phase Locked Loop) for 1µs resolution dating
  • Multi-boards synchro
  • FLIP-FLOP memory on the board
    (2 x 256Ksample.)
  • 8 selectable break sources
  • PCI Master / Slave (bus exchange)
  • Many interface terminal block
  • Drivers for Windows NT, XP and Linux 2.6 supplied and supported

Adas board
Description

PCI 160 board enables the simultaneous and isochronous acquisition of 16 analogs differential inputs as 32 TTL inputs / outputs (by two groups of 16 bits).
Each analog inputs features:

  • an instrumentation amplifier with selectable gain by software (1, 2, 5, 10)
    (protection ± 40V)
  • a 16 bits ADC which max speed is 200Ksample./s.
  • a selectable numerical filter at 128 samples

We also can find 8 analog outputs with a resolution of 14 bits (±10V FS).
PLL (Phase Locked Loop) with IRIG B synchro for 1µs resolution dating.
PCI 160 features:

  • a descriptor table measures 2Kwords
  • a double access RAM in FLIP-FLOP of 2 x 256Kwords
  • 8 selectable break sources with anti-bounce filtering

The board can be Master or Slave on the PCI to guarantee high transfer rates in realtime environment.

Iqnet
9 rue Georges Besse – BP 47 – 78330 FONTENAY LE FLEURY – FRANCE
Tél.:(33) 1 30 58 90 09 fax:(33) 1 30 58 21 33 http://www.adas.fr
Afaq
PCI 160
SPECIFICATIONS (t = 25°C)

TYPE

SIMULTANEOUS SAMPLING
16 ANALOG INPUTS & 32 DIGITAL INPUTS/OUTPUTS
WITH 8 ANALOG OUTPUTS

ANALOG INPUTS

- Number of channels

16 differential

INSTRUMENTATION AMPLIFIER

- Software programmable gain per channel 1 ; 2 ; 5 ; 10
- Input impedance 1MΩ diff / 500kΩ SE

- Signal range

± 10V FS

- Over voltage protection

± 40V (with or without supplies)

- Input current ± 30nA
- Input offset voltage ≤ ± 200+ 600/GµV
- Offset drift ≤ ± 1,7µV/°C (G = 10)
- Gain error ≤ ± 0,04 %
- Gain drift ≤ 10ppm/°C
- Non linearity ≤ ± 0,003 % FS
- CMRR 70dB (DC to 100kHz)
- Slew rate 20V / µs
- Attenuation at 100kHz (10Vpp) < 100ndB
- Noise 2,5µVpp (0,1Hz to 10Hz)

ADCs

- Type

16-bit SAR with SH

- Speed 200K Samples/S (5µs)
- INL ± 2 LSB max
- DNL ± 1 LSB max
16-bit no missing codes
- SFDR 90dB min
- SNR (20kHz) 88dB typical
- Interchannel skew 5ns
NUMERICAL FILTERING  
- Type FIR (Finite Impulse Response)
- Order 127
- Selection With or without filter by software
- Cut off frequency Programmable from Fd/50 to Fd/2,5
- Attenuation at twice cut frequency ≥ 60dB
- Transition slope ≥ 160dB/octave
- Bandwith ripple ≤ 0,02dB of DC at 0,7 Fc
ANALOG OUTPUTS  
- Number of channels 8
DACs  
- Resolution 14 bits
- Output level ± 10V FS
- Precision ± 0.02%
- Linearity ± 0.02%
- Protection Short circuit to ground
- Noise 200µVRms DC to 1MHz
- Temperature drift 20ppm / °C
- Coding Binary offset
- Power up Known status 0V
- Setting time < 31µs
- Slew Rate 0,7V/µs
- Channel isochronism Yes (All)

- Synchro trigger

Yes (By Register or internal timers)

 

PCI 160

DIGITAL I/O

- Number of channels

32 TTL / CMOS Compatibility
2 x 16-bit I/O selection

- Number of interrupt inputs 8 with Anti-bounce software switchable adjustable frequencies of 30kHz, 300kHz, 3MHz

- Timing

Synchro inputs with analog sampling or asynchronous R / W

DATING

- Type
- Coupling
- High time resolution
- Acquisition frequency
- Number of internal timers
- Timers Resolution
- RTSI

Analog IRIG B composite input or TTL external start trigger
Master / Slave boards with synchro via trigger
PLL with IRIG synchro for 1µs resolution dating
200kHz max
2
16 bits
1 TRIGGER lines

MEMORIES

- Scanning table

  • pattern
  • deph max

1008 channels
64K patterns

- Memories measurement  
  • type
  • deph
FLIP-FLOP or ONE SHOT
2 x 256Ksamples

PCI INTERFACE

- PCI
- Coupler
- Data transmission

Master / Slave 32 bits/33MHz
AMCC 5335
66Mo/s (max.)

POWER SUPPLY

- Voltage

+ 5V / 1,5A ; + 3,3V / 0,5A

PHYSICAL CHARACTERISTICS

- Format

3U / 4Te PCI FORM FACTOR

- Front panel connectors

2µD 68pts Female

 
  • One with Analog Inputs + Digital I/O
  • One with Analog Outputs
  1 x LEMO for IRIG B or TRIGGER (Input / Output)
1 x LEMO for TRIGGER 0
- LEDS 1 x Acquisition
1 x active Master
1 x Access board

ENVIRONMENT

- Range
- Operating temperature
- Storage temperature
- Relative humidity
- Vibrations
- Chocs

Industrial
- 25°C / + 85°C
- 40°C / + 100°C
90 % (without condensation)
20 Hz - 2000Hz - 4g
25g - 6ms

EUROPEAN NORMS

EMC - EN 61326
CE Compliance
ROHS - 2002/95/EC

HOW TO ORDER? PCI 160
ACCESSORIES

- STB Terminal Block

STB 534 + (STB 554 + STB 552)
STB 534 + (STB 658 + STB 532 or STB 520)

- BCI Terminal Block STB 514 + (2 x BCI 184 + 2 x BCI 140 or BCI 160)

- Cables

WR 368

 

ADAS Acquisitions Systems
  Technology Introduction
  Technology Introduction
  Product Catalog
PCI102
PCI DX6
PCI264
PCI 307
PCI 150
PCI 160
PCI 220
PCI 224
PCI 228
PCI 238
PCI 744
PCI 786
PCI LMC
CPCI SYN
CPCI 1264
CPCI 307
CPCI 1150
CPCI 1224
CPCI 1228
CPCI 412
CPCI 744
CPCI 1786
CPCI LMC
RCV20
ICV196
ICV307
ICV726
ICV150
STB512-514-534
STB532
STB6x2
ICV LMC
ACM
STB504
  Typical Applications
  Specification
OMRON
SIEMNES
EMERSON
SOR Pressure Switch
 
Copyright © 2013 Shenzhen Victory Ind. Equp. Ltd  All Rights Reserved